Designations content expressed
TCD10 50BON failure
TCD11 10TON failure
TCD12 15BON failure
TCD13 SDC abnormal operation
TCD14 from MICON crashes
TCD15 SDA crashes
TCD16 master-slave parallel communication error
TCD17 SDA, SDC serial communication error
TCD18 50BC malfunction or be cut open open E.Stop
TCD19 99G failure
TCD20 double fault into force BUFFER
TCD21 overcurrent detection (IPMFAULT)
TCD22 overvoltage detection
TCD23 SDC conservative switch abnormal
TCD24 from MICONDRAMERROR
TCD25 from MICONEEPROMERROR
TCD26 DSPSUMERROR
TCD27 multiple fault detection
TCD28 P15V voltage is abnormal
TCD29 main MICONEEPROMERROR
TCD30 main MICONNVSRAMERROR
TCD31 DSPDRAMERROR
TCD32 suppression circuit anomaly detection
TCD33 BDCC voltage is abnormal
TCD34 insufficient voltage detection
TCD35 40G, 40DON failure
TCD36 SDC mode of operation errors
TCD37 reverse rotation detection
TCD38 DSP crash detection
TCD39 100RON/OFF failure
TCD40 ROTARYENCODER failure
TCD41 low OVERSPEED
TCD42 50BOFF failure
TCD43 SPD circuit fault SDCLAN board 48V power anomalies OPBLAN-I24B or I48A I48A failure or malfunction SDCLAN-I24B
TCD44 SDCLAN breakdown in communications with OPBLAN
TCD45 BKSW Action Check
TCD46 OpenLock three consecutive back
TCD47 abnormal load detection circuit
TCD48
TCD49
TCD50 speed OVERSPEED
TCD51 speed deviation detection
TCD52 10TOFF failure
TCD53 15BOFF failure
TCD54 RE fault (U, V, W phase angle error)
TCD55 HCTOffSet deviation is too large
TCD56
TCD57 Mg.B two-stage power loop anomaly
TCD58 DLAN crashes
TCD59 story > 9 m . No detectable induction plates
TCD60 order high TABLESUMERROR
TCD61
TCD62 same period abnormal position
TCD63 SDSON failure
TCD64 SDS velocity anomaly detection
TCD65 running 40D abnormal OFF
TCD66 running 40G abnormal OFF
Close failed TCD67 leveling (40D or 40G not ON)
TCD68 SDA detected eight crashes
TCD69 SDARAMERROR
TCD70 shared RAMERROR
TCD71 main MICON crashes
TCD72 from eight MICON crash detection
TCD73 FMLPOSIOPEN failure
TCD74 rescued running multiple
TCD75 POWERMODULE overheating
TCD76 micro- speed operation time exception
TCD77 door motor overheating
TCD78 door abnormal
TCD79
TCD80
TCD81 photoelectric POSIOPEN failure
TCD82 photoelectric POSI short circuit fault
TCD83
TCD84 OLSON failure
TCD85 CLSON failure
TCD86 door action is not normal detection
TCD87 closing action is not normal detection
TCD88 outage detection
TCD89
TCD90
TCD91 DZPOSIOPEN fault ( plover , Through)
TCD92 DZPOSI short circuit fault ( plover , Through)
TCD93
TCD94
TCD95 ultimate failure purpose -order
TCD96 eventual failure elevator position
TCD97 final speed elevator malfunction
The total number of running back TCD98 rescued

FUJITEC parts
HITACHI parts
HYUNDAI parts
KONE parts
LG_SIGMA parts